Thermal Cuttofs  /  SW-5 Series


◎ CONSTRUCTION

 
     image2.png


◎ ELECTRICAL

     RATED VOLTAGE : 250V, ac (and 125V -*)
     RATED CURRENT : 5A (and 6A -*)
     INTERRUPTING CURRENT : 250V, ac 7.5A
     TRANSIENT OVERLOAD TEST CURRENT :
     dc current pulses, with an amplitude 75 A and a duration of 3 ms with 10 s intervals, are applied for 100 successive cycles

     through  the current path.


◎ TEMPERATURE


Cat NO. Tf Cutoff temperature Th UL C-UL VDE
SW-502T  72℃  70℃+2℃,-2℃ 47℃
SW-505T  77℃  77℃+0℃,-4℃ 52℃
SW-509T  84℃  84℃+0℃,-5℃ 57℃
SW-504T  98℃  96℃+2℃,-2℃ 73℃
SW-508T 100℃  100℃+0℃,-5℃ 75℃
SW-510T 109℃ 109℃+0℃,-5℃ 84℃
SW-511T 121℃ 121℃+0℃,-4℃ 94℃
SW-529T 128℃ 128℃+0℃,-5℃ 103℃
SW-538T 144℃ 144℃+0℃,-5℃ 119℃
SW-516T 152℃ 152℃+0℃,-4℃ 127℃
SW-520T 167℃ 167℃+0℃,-4℃ 144℃
SW-527T 184℃ 184℃+0℃,-6℃ 159℃
SW-525T 195℃ 195℃+0℃,-6℃ 165℃
SW-524T 228℃ 228℃+0℃,-6℃ 187℃

= Applied



◎ DIMENSIONS
                        drawing.png


dimension(mm) a b c d e
mm 35.0 ±3.5  7.5 ±0.3 42±3.5 3.0 ±0.1 0.6±0.05



◎ MARKING

   Each TCO shall be marked with:
   Trade Name : S.W.C.
   Cat No.: SW - 5XX T
   Ratings: Rated voltage (V), Rated current (A)
   Rated Functioning temperature (℃)
   Approval Mark



List of Articles
THERMAL FUSE ASSEMBLIES & OTHER PRODUCTS imagefile
Thermal Cuttofs / THERMAL FUSE ASSEMBLIES &...  
SW-5 Series imagefile
Thermal Cuttofs / SW-5 Series ◎ CONSTRUCTION...  
SW-3 Series imagefile
Thermal Cuttofs / SW-3 Series ◎ CONSTRUCTION...  
SW-2 Series imagefile
Thermal Cuttofs / SW-2 Series ◎ CONSTRUCTION ...  
SW-1 Series imagefile
Thermal Cuttofs / SW-1 Series ◎ CONSTRUCTION...  