Thermal Cuttofs  /  SW-3 Series


◎ CONSTRUCTION


     image.png


◎ ELECTRICAL

RATED VOLTAGE : 250V, ac
RATED CURRENT :15A
INTERRUPTING CURRENT : 250V, ac 22.5A
TRANSIENT OVERLOAD TEST CURRENT :
dc current pulses, with an amplitude 225 A and a duration of 3 ms with 10 s intervals, are applied for 100 successive cycles through the current path.


◎ TEMPERATURE


Cat NO. Tf Cutoff temperature Th UL C-UL VDE
SW-302T  72℃  70℃+2℃,-2℃ 47℃
SW-305T  77℃  77℃+0℃,-4℃ 52℃
SW-309T  84℃  84℃+0℃,-5℃ 57℃
SW-304T  98℃  96℃+2℃,-2℃ 73℃
SW-308T 100℃  100℃+0℃,-5℃ 75℃
SW-310T 109℃ 109℃+0℃,-5℃ 84℃
SW-311T 121℃ 121℃+0℃,-5℃ 94℃
SW-329T 128℃ 128℃+0℃,-5℃ 103℃
SW-338T 144℃ 144℃+0℃,-5℃ 119℃
SW-316T 152℃ 152℃+0℃,-4℃ 127℃
SW-320T 167℃ 167℃+0℃,-7℃ 144℃
SW-327T 184℃ 184℃+0℃,-6℃ 159℃
SW-325T 195℃ 195℃+0℃,-6℃ 165℃
SW-324T 228℃ 228℃+0℃,-6℃ 187℃
SW-328T 240℃ 240℃+0℃,-6℃ 193℃
                                                                                                                                        = Applied



◎ DIMENSIONS


                  drawing.png

dimension(mm) a b c d e
mm 35.0 ±3.5  10.5 ±0.5 35 ±3.5 4.0 ±0.2 1.2




◎ MARKING
      Each TCO shall be marked with:
      Cat No. : SW - 3XX T
      Ratings : Rated voltage (V), Rated current (A)
      Rated Functioning temperature (℃)
      Approval Mark