◎ CONSTRUCTION


   image2.png


 ◎ ELECTRICAL

RATED VOLTAGE : 250V, ac
RATED CURRENT : 2A
INTERRUPTING CURRENT : 250V, ac 3A
TRANSIENT OVERLOAD TEST CURRENT :
dc current pulses, with an amplitude 30A and a duration of 3 ms with 10 s intervals, are applied for 100 successive cycles through the current path.


◎ TEMPERATURE


Cat NO. Tf Cutoff temperature Th K.I.S UL C-UL VDE TUV MITI
SW-211T 102℃  98℃+2℃,-2℃ 70℃
SW-210T 115℃ 110℃+3℃,-2℃ 85℃
SW-215T 130℃ 125℃+2℃,-2℃ 95℃
SW-216T 133℃ 129℃+2℃,-2℃ 100℃
SW-217T 139℃ 135℃+3℃,-3℃ 105℃
SW-225T 150℃ 145℃+3℃,-2℃ 120℃

                                                                                     UL file NO : E126429  = Approved  = Applied


◎ DIMENSIONS

                       drawing.png

dimension(mm) a b c d e
mm 67.0 ±3.5  9.5 ±0.5 67±3.5 2.5±0.2 0.6±0.05



◎ MARKING
     Each TCO shall be marked with:
     Cat No. : SW - 2XX T
     Ratings : Rated voltage (V), Rated current (A)
     Rated Functioning temperature (℃)
     Approval Mark


List of Articles